Temperature and Humidity Sensor for Industrial Applications (907023)
Temperature and Humidity Sensor for Industrial Applications (907023) Metrological certification

For measuring relative air humidity and temperature

  • Measurement in the entire range between 0 to 100 % RH
  • Temperature resistant from -70 to +180 °C (depending on the type of probe)
  • Pressure resistant up to 100 bar (depending on the type of probe)
  • Robust metal case, protection type IP 65
  • Outstanding accuracy and stability
  • Graphic trend display and measured value history for the previous year
  • Traceability to NIST
  • Also available with calculation and display of dew point / frost point temperature, absolute humidity, mixing ratio, wet bulb temperature, enthalpy, volume concentration, water saturated vapor pressure, and differential temperature

Intrinsically Safe Industrial Measuring Probes for Humidity, Temperature, and Derived Measurands (907025)
Intrinsically Safe Industrial Measuring Probes for Humidity, Temperature, and Derived Measurands (907025) Ex

For measuring relative humidity and temperature

  • The calculations of dew point temperature, absolute humidity, mixing ratio, and wet-bulb temperature are possible as options
  • User-friendly, modular measuring probe concept
  • Intelligent exchange probes that save all calibration coefficients
  • Temperature resistant from -70 to +180 °C (depending on the type of probe)
  • Pressure resistant up to 100 bar (depending on the type of probe)
  • Safe operation of the complete device in potentially explosive areas of category 1G / zone 0 and 1D / zone 20 with protection cover (EU)
  • Traceable to NIST (including certificate)

Capacitive Hygrothermal Transducer with Intelligent Interchangeable Probes (907027)
Capacitive Hygrothermal Transducer with Intelligent Interchangeable Probes (907027)

For measuring relative air humidity and temperature

  • Measurement throughout the humidity range of 0 to 100 % RH
  • Intelligent interchangeable probes for simple replacement
  • For operating temperatures between -40 and +80 °C
  • Option of separate probes for humidity and temperature
  • 2 m, 5 m, or 10 m adapter cable for probe extension
  • Robust metal housing, suitable for clean rooms
  • Integrated LCD display (optional)
  • With standardized current or voltage outputs

Hygro and Hygrothermal Transducer (Hygrometric) (907031)
Hygro and Hygrothermal Transducer (Hygrometric) (907031)

For measuring relative air humidity and temperature

  • For indoor, air duct, and outdoor mounting
  • With resistance, current, or voltage outputs
  • Can be used continuously in areas of high humidity (up to 100 % RH) (duct version)
  • No voltage feed required for passive devices
  • In normal circulated air, the sensing element is largely maintenance free