Features

  • Automatic temperature compensation
  • Display visualization is selectable: large digits, bar graph, or trend display
  • Solderless connection technology
  • Calibration options according to measurand one/two/three point calibration
  • Calibration logbook
  • Activatable impedance measurement
  • Asymmetrical and symmetrical connection of ph value sensors
  • Connection option of pH-ISFET sensors through the integrated output
    to the voltage supply of the sensor
  • Selectable languages: English, German, French;
    additional languages can be added via the setup program
  • With setup program: easy-to-use programming,
    plant documentation, download of additional user languages

 

Applications

  • Drinking water monitoring and processing
  • Galvanic
  • Process technology
  • Water and wastewater technology
  • Drinking and well water, boiler supply water
  • Greenhouse technology
  • Swimming pool
  • Fishkeeping (also seawater)

Description

The device is used to measure/control the pH value, the redox voltage, or for NH3 (ammonia) concentration measurement. The function can be changed directly at the device. Depending on the measurand, combination electrodes (e.g. pH/redox combination electrodes, gas-sensitive sensors) or separate versions (glass/metal electrodes with separate reference electrode) can be connected. Temperature measurement is used as the second input value which can be performed with such a device as a Pt100/Pt1000. As a result, the ph value and NH3 measurands enable automatic temperature compensation.
The devices are operated via precise keys and a large LCD graphic display. This display allows clear legibility of the measured value. The parameter display in plain text facilitates configuration and supports the user in correctly programming the device.
The modular device structure allows the device to be adapted to the application requirements. Up to four outputs are available (for functions see block diagram).
Typical application areas:
Universally applicable in the water and wastewater industry, service/process/sewage water, drinking/well/surface water, leakage monitoring in cooling systems.

Documentation
Brochure
Software

Please take note of our General Terms and Conditions and Clauses for Paragraph 1.4 General Terms and Conditions.

Article number Product description Price of the full version
00483602

Setup JUMO AQUIS 500 (PG202599)

Download  Setup212.exe (30 days Test Version)  (83.0 MB)

additional information
price on request
Accessories

Accessory articles

Article number Product description Price / piece
Protection cover for AQUIS/202610 u. DigiLine hub price on request
Pipe mounting set for JUMO AQUIS 500 price on request
Support pillar with pedestal base, arm and chain price on request
Joint for suspended fitting price on request
Mounting for DIN rails for JUMO AQUIS 500 price on request

(in stock)

Rear panel set for JUMO-AQUIS 202560/65/66/68 Leitfaehigkeits-Messumformer CTI-920 price on request
PC interface with converter USB/TTL price on request

(in stock)

Articles in stock (for more articles see data sheet)
Filter für Verkaufsartikel-Tabelle

Reduce the table of articles by filtering the features

Article number Product description Price / piece

Basic type: transmitter / controller for pH, ORP, NH3 concentration, surface mounting housing

output 1: analog output, programmable

output 2: not to be used

output 3: relay (changeover)

output 4: not to be used

Voltage supply: AC 110..240V +10/-15%,48..63Hz

price on request

Basic type: transmitter / controller for pH, ORP, NH3 concentration, surface mounting housing

output 1: analog output, programmable

output 2: analog output, programmable

output 3: relay (changeover)

output 4: relay (changeover)

Voltage supply: AC 110..240V +10/-15%,48..63Hz

price on request

Basic type: transmitter / controller for pH, ORP, NH3 concentration, surface mounting housing

output 1: analog output, programmable

output 2: not to be used

output 3: not to be used

output 4: not to be used

Voltage supply: AC/DC 20..30V,48..63Hz

price on request