More than sensors+automation
Search

Explosion-protected surface-mounting thermostat, model ATH-Ex (60.5041)
image_605041 GOST-R Ex

  • EC type examination as per ATEX directive 94/9/EC
  • Fluid expansion
  • Pressure-resistant encapsulated micro switch
  • Self-monitoring (STW)
  • Safety cut-out (STW)

JUMO dTRANS T01 - 2-Wire Transmitter (707010)
image_707010 GOST-R Ex

  • Designs for B head or DIN rail installation
  • RTD temperature probes and thermocouples
  • Electrical isolation
  • Output, 2-wire 4 to 20 mA, HART® interface
  • Also available with Ex approval
  • Configuration with setup program 

JUMO dTRANS T02 4-Wire Transmitter (707020)
image_707020 GOST-R Ex

  • Design width 17.5 mm or 22.5 mm
  • Installation on DIN rail, 35 mm
  • Universal measuring input
  • Galvanic isolation
  • Current output, voltage output
  • LCD display
  • Ex approval
  • Configuration with setup program 

JUMO PROCESStemp RTD Temperature Probe for Process Technology (Also with ATEX Approval) (902820)
image_902820 GOST Ex

  • For temperatures between -200 and +600 °C
  • With protection tubes made of stainless steel, titanium, tantalum, Inconel, and Hastelloy
  • Available with 2-wire transmitter (4 to 20 mA/HART®) in Ex version
  • II 1/2 GD EEx ia II C T1 to T6 IP6x T80 to T400 °C1
  • II 1/2 GD EEx d II C T1 to T6 IP6x T80 to T400 °C1
  • With interchangeable measuring insert (not for Ex version)

JUMO Wtrans Transmitter RTD Temperature Probe with Wireless Data Transmission (902930)
image_902930 UL / CRUUS Ex FCC

  • For operating temperatures between -30 to +260 °C or -200 to +600 °C
  • For mobile or stationary temperature measurement
  • Open air range 300 m with interference-resistant transmission
  • No wiring work due to state-of-the-art wireless technology
  • Approval according to EC directive 94/9/EC (ATEX)

JUMO dTRANS p20 DELTA - Differential Pressure Transmitter with Display (403022)
image_403022 GOST-R Ex

  • HART® interface
  • Optional explosion protection Ex ia according to ATEX, INMETRO, GOST-R
  • Linearity: 0.07 %
  • Turn down: 1:200
  • Simple operation with rotary knob
  • Characteristic line and display also adjustable for flow measurement

JUMO dTRANS p20 - Process Pressure Transmitter with Display (403025)
image_403025 GOST-R Ex

  • HART® interface
  • Optional explosion protection Ex ia according to ATEX, INMETRO, GOST-R
  • Linearity: 0.05 %
  • Turn down: 1:50
  • Simple operation with rotary knob

JUMO dTRANS p02 DELTA pressure transmitter with display (type 40.4382)
image_404382 GOST-R Ex

Feature: for differential pressure, filling level and flow rate

  • 60 mbar... 25 bar
  • Linearity ≤ 0.1 % from standard value
  • Medium temperature: - 40... + 100 °C
  • Load on one and both sides up to a static pressure of 420 bar
  • Optional with ATEX approval

JUMO dTRANS p02 pressure transmitter with display (type 40.4385)
image_404385 GOST-R Ex

Feature: for relative pressure, absolute pressure and filling level


  • 100 mbar... 600 bar
  • Linearity: ≤ 0.1% from standard value
  • Long-term stability: < 0.1% per year
  • Medium temperature: - 40... +200 °C (SIP and CIP compatible)
  • Optional with ATEX approval

JUMO dTRANS p33 - Pressure transmitter and level measurement probe for application in explosive areas (type 40.4753)
image_404753 GOST-R Ex

Feature: with ATEX approval

  • 250 mbar ... 600 bar relative / absolute
  • Insensitive to aggressive gases, vapors and fluids
  • Medium temperature: -40... +85°C
  • Up to 200°C (SIP and CIP compatible)
  • Protection class: IP65

Particularly for the level measurement probe variant (IP 68):

  • 250 mbar to 25 bar
  • Medium temperature:-40...+70°C
  • Sturdy level measurement probe for indoor and outdoor installation

Product comparison

JUMO dTRANS p20 DELTA - Ex d Differential Pressure Transmitter with Flameproof Enclosure (403023)
image_403023 GOST-R Ex

 

  • HART® interface
  • Ex d explosion protection according to ATEX, INMETRO, GOST-R
  • Linearity: 0.07 %
  • Turn down: 1:200
  • Simple operation with rotary knob
  • Characteristic line and display also adjustable for flow measurement

JUMO dTRANS p20 Ex d - Process Pressure Transmitter with Flameproof Enclosure (403026)
image_403026 GOST-R Ex

  • HART® interface
  • Ex d explosion protection according to ATEX, INMETRO, GOST-R
  • Linearity: 0.05 %
  • Turn down: 1:50
  • Simple operation with rotary knob

Intrinsically Safe Industrial Measuring Probes for Humidity, Temperature, and Derived Variables (907025)
image_907025 Ex

For measuring relative air humidity and temperature

  • Temperature resistant between -40 °C and +180 °C (depending on the type of probe)
  • Pressure resistant up to 100 bar (depending on the type of probe)
  • Optional with calculation and output of dew point temperature, absolute humidity, and other variables
  • Intelligent exchange probes that save all calibration coefficients
  • Safe operation of the complete device in potentially explosive areas of category 1G/zone 0 and 1D/zone 20 with protection cover (EU)
  • Traceable to NIST (including certificate)

JUMO LOGOSCREEN nt Paperless Recorder (706581)
image_706581 UL / CRUUS GOST-R Ex

  • 144 × 144 mm format
  • 5.5" TFT color graphic display
  • Rotary knob and touchpad operation
  • 3 to 18 universal measuring inputs
  • Measured data storage on CompactFlash card / USB memory stick 
  • Batch reporting
  • Ethernet interface, PROFIBUS-DP interface, Modbus master/slave interface
  • Online visualization via Web browser
  • For stainless steel front including touchpad with Ex approval (zone 1 on front)

Ex-i Repeater Power Supply / Input Isolating Amplifier (707530)
image_707530 Ex

  • HART capable
  • SIL2 approval
  • Universal power supply