JUMO dTRANS p20 DELTA - Differential Pressure Transmitter with Display (403022)
JUMO dTRANS p20 DELTA - Differential Pressure Transmitter with Display (403022) GOST-R Ex

  • HART® interface
  • Optional explosion protection Ex ia according to ATEX, INMETRO, GOST-R
  • Linearity: 0.07 %
  • Turn down: 1:200
  • Simple operation with rotary knob
  • Characteristic line and display also adjustable for flow measurement

JUMO dTRANS p20 DELTA Ex d - Differential Pressure Transmitter with Flameproof Enclosure (403023)
JUMO dTRANS p20 DELTA Ex d - Differential Pressure Transmitter with Flameproof Enclosure (403023) GOST-R Ex

 

  • HART® interface
  • Ex d explosion protection according to ATEX, INMETRO, GOST-R
  • Linearity: 0.07 %
  • Turn down: 1:200
  • Simple operation with rotary knob
  • Characteristic line and display also adjustable for flow measurement

JUMO dTRANS p20 - Process Pressure Transmitter with Display (403025)
JUMO dTRANS p20 - Process Pressure Transmitter with Display (403025) GOST-R EHEDG Ex

  • HART® interface
  • Optional explosion protection Ex ia according to ATEX, INMETRO, GOST-R
  • Linearity: 0.05 %
  • Turn down: 1:50
  • Simple operation with rotary knob

JUMO dTRANS p20 Ex d - Process Pressure Transmitter with Flameproof Enclosure (403026)
JUMO dTRANS p20 Ex d - Process Pressure Transmitter with Flameproof Enclosure (403026) GOST-R Ex

  • HART® interface
  • Ex d explosion protection according to ATEX, INMETRO, GOST-R
  • Linearity: 0.05 %
  • Turn down: 1:50
  • Simple operation with rotary knob

JUMO dTRANS p02 DELTA Pressure Transmitter with Display (404382)
JUMO dTRANS p02 DELTA Pressure Transmitter with Display (404382) GOST-R Ex

Feature: for differential pressure, filling level, and flow

  • 0 - 60 mbar DP to 0 - 25 bar DP
  • Linearity: ≤ 0.1 % of end value
  • Temperature of medium: -40 to +100 °C
  • Load on one and both sides up to a static pressure of 420 bar
  • ATEX approval available as an option

JUMO dTRANS p02 - Pressure Transmitter with Display (404385)
JUMO dTRANS p02 - Pressure Transmitter with Display (404385) GOST-R Ex

Feature: for relative pressure, absolute pressure, and level

  • -100 to 100 mbar – -1 to 600 bar relative, 0 to 600 mbar – 0 to 25 bar absolute
  • Linearity: ≤ 0.1 % from end value
  • Long-term stability: < 0.1 % per year
  • Medium temperature: -40 to +200 °C (SIP and CIP capable)
  • ATEX approval available as an option

JUMO dTRANS p33 - Pressure Transmitter and Level Probe for Application in Ex-Areas (404753)
JUMO dTRANS p33 - Pressure Transmitter and Level Probe for Application in Ex-Areas (404753) GOST-R Ex

Feature: with ATEX approval

  • 0 to 250 mbar – 0 to 600 bar relative, 0 to 600 mbar – 0 to 25 bar absolute
  • Impervious to aggressive gases, vapors, and liquids
  • Medium temperature: -40 to +85 °C
  • Up to 200 °C (SIP and CIP compatible)
  • Protection type: IP65 

Particularly for the level probe variant (IP68):

  • Medium temperature: -40 to +70 °C
  • Sturdy level probe for indoor or outdoor installation

Product comparison

JUMO exTHERM-AT (605055)
JUMO exTHERM-AT (605055) GOST-R GOST Ex

  • Can be directly applied in zones 1 and 2 or 21 and 22
  • Switching capacity 16 A as standard, optionally 25 A
  • Admissible ambient temperature -55 °C to +70 °C
  • Thermowell for zone 0 available as an accessory
  • Single thermostat and double thermostat

JUMO safetyM STB/STW Ex - Safety Temperature Limiter and Safety Temperature Monitor According to DIN 14597
JUMO safetyM STB/STW Ex - Safety Temperature Limiter and Safety Temperature Monitor According to DIN 14597 Ex DIN GL SIL PL

  • 1 sensor variant
    Ex II (1) (2) (3) G (b1) [Ex ia Ga] [e pz] IIC
    Ex II (1) (2) (3) D (b1) [Ex ia Da] [p Dc] IIIC
  • 2 sensor variant
    Ex II (1) (1) (2) G (b2) [Ex ia Ga] [e py] IIC
    Ex II (1) (1) (2) D (b2) [Ex ia Da] [p Db] IIIC
  • Monitoring of potential sources of ignition according to EN 13463 IPL 2
  • Temperature monitoring unit for monitoring of potential sources of ignition according to EN 50495 SIL2
  • Minimum pressure monitoring SIL2
  • Intrinsically safe input [Ex ia] according to EN 60079-11
  • Safety-relevant limit value relay (230 V, 3 A)
  • Pre-alarm absolute or adjustable as a margin from the limit value
  • Default actual value output
  • Approvals for DIN EN 14597, ATEX, PED
  • Optional approvals: SIL, PL, GL

JUMO LOGOSCREEN nt - Paperless Recorder (706581)
JUMO LOGOSCREEN nt - Paperless Recorder (706581) UL / CRUUS GOST-R Ex

  • 144 × 144 mm format
  • 5.5" TFT color graphics screen
  • Rotary knob and touchpad operation
  • 3 to 18 universal measuring inputs
  • Measured data storage on CompactFlash® card / USB memory stick 
  • Batch reporting
  • Ethernet interface, PROFIBUS-DP interface, Modbus master/slave interface
  • Online visualization via web browser
  • Optionally available with stainless steel front and touchpad

JUMO LOGOSCREEN fd - Secure Data Management and FDA-Compliant Measured Data Recording (706585)
JUMO LOGOSCREEN fd - Secure Data Management and FDA-Compliant Measured Data Recording (706585) UL / CRUUS Ex

  • Complies with FDA 21 CFR – part 11
  • Up to 50 users
  • Electronic signature
  • Straight-forward security management
  • Simple operation with control knob or touchpad

JUMO dTRANS T01 - 2-Wire Transmitter (707010)
JUMO dTRANS T01 - 2-Wire Transmitter (707010) GOST-R Ex

  • Designs for B head or DIN rail installation
  • RTD temperature probes and thermocouples
  • Electrical isolation
  • Output, 2-wire 4 to 20 mA, HART® interface
  • Also available with Ex approval
  • Configuration with setup program 

JUMO dTRANS T02 - Four-Wire Transmitter (707020)
JUMO dTRANS T02 - Four-Wire Transmitter (707020) GOST-R Ex IECEx

  • Design width 17.5 mm or 22.5 mm
  • Installation on DIN rail, 35 mm
  • Universal measuring input
  • Galvanic isolation
  • Current output, voltage output
  • LCD display
  • Ex and IECEx approval
  • Configuration with setup program 

Ex-i Repeater Power Supply / Input Isolating Amplifier (707530)
Ex-i Repeater Power Supply / Input Isolating Amplifier (707530) Ex SIL

  • HART capable
  • SIL2 approval
  • Universal power supply

JUMO PROCESStemp RTD Temperature Probe for Process Technology (Also with ATEX Approval) (902820)
JUMO PROCESStemp RTD Temperature Probe for Process Technology (Also with ATEX Approval) (902820) GOST Ex

  • For temperatures from -200 to +600 °C
  • With protection tubes made of stainless steel, titanium, tantalum, Inconel, and Hastelloy
  • Available with 2-wire transmitter (4 to 20 mA/HART®) in Ex version
  • II 1/2 G Ex ia IIC T1 to T6 Ga/Gb¹
  • II 1/2 D Ex ia IIIC T80 °C to T400 °C IP66 Da/Db¹
  • II 1/2 G Ex d IIC T1 to T6 Ga/Gb¹
  • II 1/2 D Ex tb IIIC T80 °C to T400 °C IP66 Da/Db¹
  • With interchangeable measuring insert (not for ATEX basic types)

 

¹ See description

ATEX/IECEx RTD Temperature Probe with Connecting Cable Acc. to DIN EN 60751 (902821)
ATEX/IECEx RTD Temperature Probe with Connecting Cable Acc. to DIN EN 60751 (902821) EHEDG Ex IECEx

  • For temperatures from -100 to +600 °C
  • As single, double, or triple RTD temperature probe in two-wire, three-wire, or four-wire circuit
  • Shielded connecting cables (silicone, PTFE, metal braiding/glass fiber, PVC, PUR, FEP, RADOX®, BETAflam®)
  • Application-specific design types

JUMO Wtrans T - RTD Temperature Probe with Wireless Data Transmission (902930)
JUMO Wtrans T - RTD Temperature Probe with Wireless Data Transmission (902930) UL / CRUUS Ex FCC

  • For stationary and mobile measurements
  • Measuring ranges: -30 to +260 °C or -200 to +600 °C
  • Radio frequency: 868.4 MHz or 915 MHz
  • Also available with ATEX approval
  • Open air range up to 300 m
  • Configurable transmission interval (1 to 3600 s)

Intrinsically Safe Industrial Measuring Probes for Humidity, Temperature, and Derived Variables (907025)
Intrinsically Safe Industrial Measuring Probes for Humidity, Temperature, and Derived Variables (907025) Ex

For measuring relative air humidity and temperature

  • The calculations of dew point temperature, absolute humidity, mixing ratio, and wet bulb temperature are possible as options
  • User-friendly, modular measuring probe concept
  • Intelligent exchange probes that save all calibration coefficients
  • Temperature resistant between -40 °C and +180 °C (depending on the type of probe)
  • Pressure resistant up to 100 bar (depending on the type of probe)
  • Safe operation of the complete device in potentially explosive areas of category 1G / zone 0 and 1D / zone 20 with protection cover (EU)
  • Traceable to NIST (including certificate)