JUMO
More than sensors+automation
Home
Products
315 × 171 and 171 × 315 mm formats
5" color graphic display
Two-state/three-state continuous controller, three-step controller, continuous controller
4 control channels
Inputs/outputs can be expanded in a modular structure
99 programs with real-time clock
Math and logic function
Recording function
Modbus interface, PROFIBUS-DP interface
Retrofitting PCBs for JUMO IMAGO F3000 Activation of the recording function
Wired ready for use
2-state controller
Pt100, Pt1000, Fe-CuNi "L" or NiCr-Ni "K"
Load circuit up to 16A
Modbus port
Process visualization with network function
Real time operation
Batch related and continuous recording
Process/group/trend pictures
Alarm/event lists
Design width 22.5 mm
Installation on DIN rail, 35 mm
Heating or cooling operation
LCD display
10 A relay (changeover contact)
Configuration with setup program
76 × 36 mm format
Heating or cooling operation
Defrosting function
Counters for operating hours and service
LCD display
Two relays
Configuration with setup program
76 × 36 mm format
Heating or cooling operation
Defrosting process electrically or with hot gas
Counters for operating hours and service
Real-time clock, Modbus interface, data logger
LCD display
Configuration with setup program
Can be configured as safety temperature limiter (STB) or safety temperature monitor (STW)
1oo2D architecture
Approvals for DIN EN 14597, SIL3, PLe, UL
Two relay outputs can be used as pre-alarm or limit value alarm
Pre-alarm absolute or adjustable as a margin from the limit value
Digital input filter with configurable filter time constant
Internal and external unlocking possible
Design width 22.5 mm
Installation on DIN rail, 35 mm
Approval according to DIN EN 14597, cULus
Universal measuring input (including standard signal)
LCD display
Configuration with setup program
Configurable as temperature limiter (TB) or temperature monitor (TW)
Approval according to DIN EN 14597
17 linearizations can be set
Input 2 × Pt100 for differential measurement
Internal and external unlocking possible
DIN CERTCO tested device
Formats 48x24, 96x48 mm
Digit height 10 or 20 mm
Universal measuring input
2 alarm outputs
Min, Max and Hold function
Protection type IP66
76 × 36 mm format
Digit height 13 mm
Symbols for temperature unit
Alarm output
Protection type IP65
96 x 48 mm format
Digit height 18mm and 7mm
Up to 4 display channels
Process text and alarm signal text with color change and running text
Up to 2 universal measuring inputs
Outputs have modular extensibility
Min/max function and hold function
Math and logic function
Modbus interface, PROFIBUS-DP interface
48 × 24, 48 × 48, 48 × 96, 96 × 48, 96 × 96 mm formats
Two-state/three-state controller
Timer and ramp function
Design width 22.5mm
Installation on DIN rail 35mm
2-/3-state controller
LCD display
Formats 48x48, 48x96, 96x96mm
2/3-state, 3-state modulating and continuous controller
Timer, ramp function
Modbus interface
Input for PT100 , NiCr-Ni "K"
Various probe versions
Data logger up to 9999 measured values
Min. / max. value recording
USB interface
Battery type AA
48 × 48 mm, 48 × 96 mm, 96 × 48 mm, 96 × 96 mm formats
2-state/3-state continuous controller, three-step continuous controller
Inputs/outputs have modular extensibility
Timer/ramp/program function
Math and logic function
Modbus interface, PROFIBUS-DP interface
Approval DIN EN 14597
48 × 48 mm, 48 × 96 mm, 96 × 96 mm formats
2-state/3-state continuous controller, three-step continuous controller
Inputs/outputs have modular extensibility
Special functions for plastics processing machines
Math and logic function
Interface for Modbus master/slave, current 0/20 mA, PROFIBUS-DP
Retrofitting PCBs for di308, dTRON3xx (plast),
Activation of the math and/or logic module
External relay / logic modules for DICON 40x/50x, IMAGO500, Logoline 500d, Logoprint 500
96 × 96 mm format
Two-state controller, three-state controller, three-step controller, position controller, continuous controller
Inputs/outputs can be expanded in a modular structure
Ramp function, program function
Math and logic function
Modbus interface, PROFIBUS-DP interface
Bar graph display, plain text display
Retrofitting PCBs for DICON 40x/50x
Activation of the math or logic module
96 × 96 mm format
Two-state controller, three-state controller, three-step controller, position controller, continuous controller
Inputs/outputs can be expanded in a modular structure
10 programs with real-time clock
Math and logic function
Modbus interface, PROFIBUS-DP interface
Bar graph display, plain text display, program status display
144 × 130 mm format (installation dimensions 92 × 92 mm)
5" color graphic display
Two-state controller, three-state controller, three-step controller, position controller, continuous controller
8 control channels
Inputs/outputs have modular extensibility
50 programs with real time clock
Math and logic functions
Recording function
Modbus interface, PROFIBUS-DP interface
Retrofitting PCBs for IMAGO 500 Activation of the extra codes
Design width 91 mm
Installation on a DIN rail 35mm
2-state/3-state, 3-state modulating controller, positioner, continuous controller,
2 universal measuring inputs
3 outputs
Design width 91 mm
Installation on a DIN rail 35mm
4 outputs
Design width 91 mm
Installation on a DIN rail 35mm
4 / 8 measuring inputs
Design width 91 mm
Installation on a DIN rail 35mm
2 outputs
Design width 91mm
Installation on a DIN rail 35mm
Real time clock
Programming via ST code
8 digital inputs
6 outputs
Format 151.6 x 80.3 mm
Two-line LCD display
16 process-, alarm-windows
Design width 91 mm
Installation on a DIN rail 35mm
Modbus interface
Modem support
144 × 144 mm format
24-digit LED dot matrix display
Display and text printing
1, 2, or 3 universal measurement inputs
Text printout and report functions
Math and logic module
Modbus interface
144 × 144 mm format
24-digit LED dot matrix display
3 / 6 universal measurement inputs
Text printout and report functions
Math and logic module
Modbus interface
144 × 144 mm format
5" color graphic display
3 / 6 universal measurement inputs
Measured data storage on CompactFlash card
Math and logic function
Ethernet interface, Modbus interface (optional)
200 × 144 mm format (installation dimensions 138 × 138 mm)
5.7" color graphic display
6 / 12 universal measurement inputs
Measured data storage on CompactFlash card
Batch reporting
Ethernet interface, PROFIBUS-DP interface, Modbus interface
Data management in compliance with FDA 21 CFR Part 11
200 × 144 mm format (installation dimensions 138 × 138 mm)
5.7" color graphic display
6 / 12 universal measurement inputs
Measured data storage on CompactFlash card
Batch reporting
Ethernet interface, PROFIBUS-DP interface, Modbus interface
144 × 144 mm format
5.5" TFT color graphics screen
Rotary knob and touchpad operation
3 to 18 universal measuring inputs
Measured data storage on CompactFlash® card / USB memory stick
Batch reporting
Ethernet interface, PROFIBUS-DP interface, Modbus master/slave interface
Online visualization via web browser
Optionally available with stainless steel front and touchpad
Designs for B head or DIN rail installation
RTD temperature probes and thermocouples
Electrical isolation
Output, 2-wire 4 to 20 mA, HART® interface
Also available with Ex approval
Configuration with setup program
Design width 17.5 mm or 22.5 mm
Installation on DIN rail, 35 mm
Universal measuring input
Galvanic isolation
Current output, voltage output
LCD display
Ex approval
Configuration with setup program
Designs for B head, J head, or DIN rail installation
PT100
Analog measured value processing
Output, 2-wire 4 to 20 mA, 3-wire 0 to 10 V
Configuration with setup program
Design width 22.5 mm
Pt100, Pt1000, and potentiometer
Adjustable with DIP switches
Analog measured value processing
Output 0(4) to 20 mA, 0 to 10 V
Configuration with setup program
Transmission frequency 868.4 MHz
Open air range up to 300 m
Universal measuring input
Customer-specific linearization (40 pairs of value or 4th order polynomial)
3.6 V/2.2 Ah Li battery in AA format
Straight-forward setup program including OnlineChart (optional)
Design width 22.5mm, 30mm, 45mm, 75mm
Installation on DIN rail, G rail
Electrical isolation
Output DC 24V 22mA, 25mA, 55mA
Load currents 25A, 50A
Load voltages 265V, 530V
Control voltage 4...32V DC
Without heat sink
Load currents 20A, 30A, 45A,
Load voltages 265V, 660V
Control voltage 4...32V DC
Single phase, 3 phase version
With heat sink
Load currents 70 A, 100 A, 200 A
Load voltages up to 380 V DC
Wall mounting
Patented control procedure
Amplitude control
Direct control of low voltage heating elements (SIC, MoSi2 )
Simple configuration of the device through plain text display
Setup program for configuration via USB interface
Transmission of the setup data is possible even without voltage supply to the device (USB port supplies power)
Network load optimization through dual energy management
RS422/485 interface or PROFIBUS-DP
Generalized phase mode, burst-firing mode, and half-wave control
Soft start function
Current limiting
Resistance monitoring and limitation for MoSi2 heating elements
Teach-in function for the detection of partial load failure
Integrated diagnostic systems (e.g. rotating field detection)
Simple configuration of the device through plain text display
Setup program for configuration via USB interface
Transmission of the setup data is possible even without voltage supply to the device (USB port supplies power)
Network load optimization through dual energy management
RS422/485 interface or PROFIBUS-DP
Burst-firing mode
Soft start function with pulse groups
Resistance monitoring and limitation for MoSi2 heating elements
Teach-in function for the detection of partial load failure
Integrated diagnostic systems (e.g. rotating field detection)
Spare parts for thyristor power units and IGBT power converters
Process mapping for up to 30 input/output modules
Ethernet interface with integrated Web server
1 USB interface
64 limit values are monitored
PLC according to IEC 61131-3 (option)
9 program generators (option)
2 field bus interfaces (option)
Math and logic module (optional, activation for all connected controller modules)
Up to four PID controller channels, each with two parameter sets and four setpoint values
Self-optimization with the oscillation or step response method
Independent operation
Two high-quality universal analog inputs for thermocouple, RTD temperature probe, resistance transmitter, resistance/potentiometer, and standard signals
Customer-specific linearization (up to 4th order polynomial)
Two digital inputs DC 0/24 V
Two digital outputs as relays with normally open contact AC 230 V/3 A or logic DC 0/15 V
Inputs and outputs can be extended (option)
All analog inputs are galvanically isolated from each other
Limit value monitoring
Four relay outputs with changeover contact AC 230 V/3 A
Automatic configuration after module insert replacement (Plug and Play)
Connection of outputs on front
Removable terminal strips with Push-In technology
Quick wiring of operating voltage and system bus provided by simple module connection principle
Four high-quality universal analog inputs for thermocouple, RTD temperature probe, resistance transmitter, resistance/potentiometer, and standard signals
All analog inputs are galvanically isolated from each other
Customer-specific linearization (up to 45 pairs of values or 4th order polynomial)
Limit value monitoring
1 DC 0/24 V digital input
Eight analog inputs for RTD temperature probes in 2-wire circuit
Limit value monitoring
1 DC 0/24 V digital input
12 digital inputs/outputs
Channels can be configured individually as DC 0/24 V digital inputs or DC 0/24 V digital outputs / max. 500 mA
External voltage supply for digital inputs/outputs via terminal on front
RJ45 system bus connections on front (1 × Bus In, 2 × Bus Out)
Decentralized module assignment supported
Addressing via rotary coding switch for special applications
Electrical isolation of interfaces on front
Supply of operating voltage
Quick wiring of operating voltage and system bus provided by simple module connection principle
21.3 cm (8.4") TFT touchscreen with a resolution of 640 × 480 pixels and 256 colors
Pre-defined screen masks for controller, program generator, and recording function
Customer-specific process screens
User administration
Configuration access to the overall system
Recording function (option), compatible PC software: PCA3000 from version 177.03.xx/3.06, PCC from version 178.03.xx/3.06
Integrated Web server
Ethernet interface
Three USB interfaces
Two RJ45 system bus connections (1 × Bus In, 1 × Bus Out)
Two serial interfaces (option) as RS232 or RS422/485 for barcode scanner and Modbus RTU master/slave
AC 100 to 240 V wide-range input
Quick-connect spring-clamp terminals
Robust metal case
Expansion boards for mTRON T
Enabling of extra codes